General Machine Operation
The system is generally fully automatic in operation.
To switch on
Proceed as follows:
Check air applied (pressure gauge on air inlet above 4
bar)

Check power applied (Red light on control panel)
Ensure all emergency stops are off (pulled out).
Press the green start button on the control cabinet. Green
lamp should come on.
Allow bottles into the leak tester.
To Switch off
Press the Stop button on the control panel.
To Verify Operation
If required, correct leak tester operation can be verified by passing a sample
bottle with a test hole repeatedly through the leak tester, once for each
channel. Alternatively use the optional
self test system.
To Clear a Bottle Jam
Press the Stop button. Clear the leak tester area of bottles. Make sure the stop
button is pulled back out, then press the green start button. Allow bottles into
the leak tester again.